Solvent-Free Lamination Quality Control

Jan 10, 2025 Leave a message

As the control of VOCs emission becomes stricter, solvent-free lamination is being used by more and more flexible packaging companies due to its advantages of zero VOCs emission, fast speed, low energy consumption, and small amount of glue. So how to control the quality of solvent-free lamination?

 

1.Cleanliness. The fixed roller, metering roller, coating roller, coating pressure roller, composite steel roller, composite pressure roller, glue mixing tube, glue mixer's main agent and curing agent barrels and each guide roller must be clean and free of foreign matter. Otherwise bubbles and white spots will appear on the surface of the laminate film.

 

2.Temperature control The main agent of solvent-free glue is Isocyanate polymers (usually called NCO component), and the curing agent is polyol polymer (usually called OH component). The density, viscosity, performance of the main agent and curing agent, as well as the service life, use temperature, aging temperature and time of the glue will affect the composite quality.

 

Since there are no small solvent molecules in solvent-free polyurethane adhesives, the intermolecular force is large and hydrogen bonds are formed, and the viscosity is very high at room temperature. The viscosity can be effectively reduced by heating, but too high a temperature can easily lead to gelation and generate high molecular weight resins, making coating difficult or uneven, so it is very important to control the coating temperature.

 

The higher the temperature before mixing, the lower the viscosity; the higher the temperature after mixing, the higher the viscosity. The temperature adjustment of the metering roller and the coating roller mainly depends on the viscosity of the adhesive. The temperature of the metering roller of the glue with higher viscosity should be increased accordingly, and the temperature of the composite hot roller can generally be controlled at around 50±5℃.

 

3.According to the different composites material, different glue amounts can be used, as shown in Table 1 is the approximate range of glue amounts, and the control of glue amount in production is mainly determined by the gap and speed ratio between the metering roller and the fixed roller.

info-839-425

4.Tension control. The initial adhesion of solvent-free lamination is quite low. If the tension of the front and rear films does not match, the shrinkage of the films may be different during the aging process, resulting in apparent bubbles and tunnels.

 

Generally, the tension of the second unwinding should be reduced as much as possible. For thicker films, the tension and the temperature of the laminating hot roller should be appropriately increased. Try to ensure that the laminated film does not have curling. The taper tension control is also very important and should be adjusted accordingly with the thickness of the film.

 

5.Pressure control. Since the coating roller controls the amount of glue applied by the gap between the two smooth rollers and the speed ratio, the coating pressure will directly affect the amount of glue applied (especially for glue with good leveling properties). The greater the pressure, the smaller the amount of glue applied.

 

6.Compatibility of ink and glue: When changing the ink manufacturer or glue system, it is best to do a compatibility test.

 

7.Control humidity. Adjust the ratio of the main agent to the curing agent according to the change of humidity. The solvent-free composite speed is very fast. If the humidity is too high, the composite film coated with glue will still come into contact with moisture in the air, consuming part of the isocyanate NCO, resulting in glue not drying and poor peeling.

 

The solvent-free composite machine speed is high, and the substrate used will generate static electricity, causing the printed film to easily absorb dust and impurities, affecting the appearance quality of the product. Therefore, the production operation environment should be relatively closed, so that the workshop is kept within the required temperature and humidity range.

 

8. Glue preheating. Generally, glue needs to be preheated before entering the cylinder, and the mixed glue needs to be heated to a certain temperature before it can be applied to ensure the transfer rate of the glue.

 

9.Maintenance of metering pumps. When using two-component adhesives, the metering pump is a very critical component, and it must be ensured that the metering pump operates well. The compressed air entering the metering pump must be kept dry, and a dehumidifier should be installed if necessary.

 

If there is moisture in the compressed air, it will have a great impact. On the one hand, it may cause changes in tension; on the other hand, it will cause the glue pump to be blocked, resulting in incorrect adhesive ratios. At the same time, the adhesive will solidify in the glue pump and is not easy to clean.

Send Inquiry